Product Line-Up

Various options can be fitted (e.g. material properties, cooling unit, heating system, circulating system etc) depending on the material and application.

Super-Micronization Machine 「NANOMIZER」 Laboratory Type

Summary

Simple operation making the impossible possible!
NANOMIZER is the best wet-type micronizer for your research and development needs.

Characteristics

Main Specifications
Specifications NMS-200L NMS-200ED NMS-2000ARL
D10 D08 D10 D10
  NMS-200L NMS-200ED NMS-2000ARL
Max
Operating
Pressure
200 MPa 200 MPa 200 MPa 200 MPa

Max
Output
Capacity

7.8 mL/s 5.0 mL/s 15.0 mL/s(Double Dispense) 6.9 mL/s
Max
Average Capacity
6.4 L/h 4.1 L/h 16 L/h(Fixed Dispense) 10 L/h
External
Dimensions
W 548×D 349×H 517 W 767×D 383×H 757 W 723×D 282×H 439
Weight 38 kg 85 kg 67 kg
Plunger Diameter 10 mm 8 mm 10 mm 10 mm
Stroke Max. 50 mm
Driving
Method
Turbo Motor + Ball Screw Type Pneumatic
Driving
Force
0.75 kW 1.5 kW+1.5 kW Φ200 Air Cylinder

Max
Volume
Per Shot

3.9 mL 2.6 mL 7.85 mL 3.9 mL

Internal
Stagnating
Volume

3.0 mL 3.3 mL 66.5 mL 3.0 mL
Min
Sample Volume
6 mL 75 mL 10 mL
Sample
Input
Method

Luer Lock Fitting,
100ml Glass Funnel

500ml SUS Funnel

Luer Lock Fitting,
100ml Glass Funnel

Max Input Particle Size Max. 30μm(Recommended 10μm & below)
Operating Method Colour LCD Touch Panel 1 Cycle / Continuous Operation Switch
Operating Mode

Manual Mode (1 Cycle), Automatic Mode (Continuous: Time or Number of Cycles)

Fixed Dispense Mode, Double Dispense Mode, Heterogeneous Dispense Mode, Single Unit Operation

2 Operating Modes:
1 Cycle or Continuous

Control System Pressure Control using Dispensing Speed Pressure Control using Dispensing Speed Pressure Control using Regulator
Electrical Power 3 Φ AC 200 V
Power
Consumption
1.5 kVA 6 kVA
Power Cable AC 250 V 15 A 5 m AC 250 V 30 A 5 m
Electrical Connection Socket: Ground + 3P Outlet
No Plug
Air Supply Above 900 NL/min
Cooling Water Optional 5L/min (at 15℃)

Maximum operating pressure varies according to the speed of the plunger movement at that time.
 Although the equipment is designed based on a maximum pressure of 200MPa, a lower operating
 pressure that will not overload or overheat the motor is recommended.

Download catalogue here

Micronization Machine 「NANOMIZER」 Mass Production Type

Summary

 Achieving space saving and energy conservation in production processes through high efficiency,
 high quality in-line emulsification and dispersion!

Characteristics

Main Specifications
Specifications NMS-BUPS200
  NMS-BUPS200
Pressure 200 MPa(Max)
Capacity 64 L/h(Max)
Power 3 phase AC 200 V 22 kVA
Dimensions 600(W)×1600(D)×1195(H)mm
Weight 500 kg

 Download catalogue here